Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
   
   FLOW METERS
– 
FLOW METER
   
   FLOW METERS (Compact Type)
– 
SQUARE EDGE ORIFICE FLOW METER
– 
CONDITIONING FLOW METER
   
   FLOW ELEMENTS
– 
ORIFICE PLATE ASSEMBLY
– 
INTEGRAL ORIFICE PLATE ASSEMBLY, METER RUN ASSEMBLY & HONED METER RUN ASSEMBLY
– 
FLUID-BAR (AVERAGING PITOT TUBE)
– 
FLOW NOZZLES
– 
VENTURI TUBES
– 
AEROFOIL
   
   VALVE MANIFOLDS & ACCESSORIES
– 
ISOLATION VALVE NEEDLE TYPE
– 
TWO WAY MANIFOLD
– 
THREE WAY MANIFOLD
– 
FIVE WAY MANIFOLD
– 
SYPHON, AIR HEADER, CONDENSING POTS
 
   WATER FLOW LABORATORY
– 
WATER FLOW LABORATORY






















   
 

VALVE MANIFOLDS & ACCESSORIES – FIVE VALVE MANIFOLD

 

Five valve manifold is used in combination with differential pressure transmitter providing isolation, equalizing & drain/test functions. It allows the operator to isolate zero adjust the instrument & safely drain any trapped medium. The drain ports have dual functions. They can also be used as test or calibration connections after the draining operation.


  FIVE VALVE MANIFOLD
Direct Mounting
 
This manifold is suitable for direct mounting to a differential pressure transmitter which has outlet flanged connection centers at 54 x 41.3 mm. 2 Nos. of neoprene rubber manifold to instrument sealing rings & 4 nos. Of 7/16” UNF carbon steel bolts are supplied with the manifold.
 
...............................................................................................................................................................................................
 
 
  FIVE VALVE MANIFOLD   Remote Mounting
 
This manifold is suitable for remote mounting from differential pressure transmitter. The base mounting holes are suited to 2 nos. of M6 bolts.
 
...............................................................................................................................................................................................
 
 
  STANDARD BONNET ASSEMBLY
 
 
 
1. T bar handle for low torque operation
2 & 7.
Spindle & separate spindle head, provide two piece non-rotating spindle arrangement. This result in better sealing & longer life. Spindle head has ground 0.8 micron Ra finished for 100 % shut off & sealing
3. Gland adjuster for in service adjustment
4. Lock nut
5. Dust cap, prevents ingress of contaminations to operating threads
6. Gland packing
8. Gland body
9. Washer, to seal the bonnet to the body
10. Lacking pin, prevent detachment of the bonnet from the body
11. Hex screw
Items 1,3,4,5,10 & 11 are cllassed as non - wetted, i.e. parts which are never in contact with the process medium.



 