A Two valve manifold combines facilities
for isolation, calibration, test & venting of the instrument.
This manifold is generally used with pressure gauges, transmitters,
pressure switches & similar pressure measurement equipment.
The manifold are available in number of configurations to
suit every type of installation. A variety of mounting / support
methods are possible . |
|
Material |
: |
CS, SS 316, SS 304, Monel, Hastelloy C |
|
|
Vertical
Inlet, Outlet & Drain/Test Connection |
|
|
|
For line installation and suitable for wall mounting using 2 nos. of M8 bolts |
|
Inlet |
|
Outlet |
|
Drain / Test |
|
: |
|
: |
|
|
|
|
|
Horizontal
Inlet, Instrument Flanged Outlet & Drain/Test
Connection |
|
|
Suitable for direct mounting
to gauge pressure transmitters. 1 No of P.T.F.E. ring,
manifold to instrument sealing ring with 2 Nos. of
7/16” UNF carbon steel bolts are included with
the manifold. The drain valve bonnet is on left hand
side. The manifold can be base mounted using locating
pin & mounting bolt. |
|
Inlet |
|
Outlet |
|
Drain / Test |
|
: |
Flanged (12.0 mm hole
at 41.3 mm apart )
|
: |
|
|
|
|
|
Vertical
Inlet, Outlet & Drain/Test Connection for PT
3051 |
|
|
Suitable for direct mounting
to pressure transmitter, Fisher-Rosement model PT
3051. |
|
Inlet |
|
Outlet |
|
Drain / Test |
1/2”NPT(F) |
: |
1/2”NPT(F) |
: |
1/4”NPT(F) |
|
|
|
|
| |